Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Medical Journal ; (24): E018-E018, 2020.
Article in English | WPRIM | ID: wpr-811527

ABSTRACT

Background@#Medicines for the treatment of 2019-novel coronavirus (2019-nCoV) infections are urgently needed. However, drug screening using live 2019-nCoV requires high-level biosafety facilities, which imposes an obstacle for those without such facilities or 2019-novel coronavirus (2019-nCoV). This study aims to repurpose the clinically approved drugs for the treatment of coronavirus disease 2019 (COVID-19) in a 2019-nCoV related coronavirus model.@*Methods@#A 2019-nCoV related pangolin coronavirus GX_P2V/pangolin/2017/ Guangxi was described. Whether GX_P2X uses angiotensin-converting enzyme 2 (ACE2) as the cell receptor was investigated by using small interfering RNA (siRNA) -mediated silencing of ACE2. The pangolin coronavirus model was used to identify drug candidates for treating 2019-nCoV infection. Two libraries of 2406 clinically approved drugs were screened for their ability to inhibit cytopathic effects on Vero E6 cells by GX_P2X infection. The antiviral activities and antiviral mechanisms of potential drugs were further investigated. Viral yields of RNAs and infectious particles were quantified by quantitative real-time polymerase chain reaction (qRT-PCR) and plaque assay, respectively.@*Results@#The spike protein of coronavirus GX_P2V shares 92.2% amino acid identity with that of 2019-nCoV isolate Wuhan-hu-1, and uses ACE2 as the receptor for infection just like 2019-nCoV. Three drugs-cepharanthine (CEP), selamectin and mefloquine hydrochloride exhibited complete inhibition of cytopathic effects in cell culture at 10 μmol/L. CEP demonstrated the most potent inhibition of GX_P2V infection, with a concentration for 50% of maximal effect [EC50] of 0.98 μmol/L. The viral RNA yield in cells treated with 10 μmol/L CEP was 15,393-fold lower than in cells without CEP treatment ([6.48±0.02]×10-4 vs. 1.00±0.12, t=150.38, P<0.001) at 72 h post-infection (p.i.). Plaque assays found no production of live viruses in media containing 10 μmol/L CEP at 48 h p.i. Furthermore, we found CEP has potent antiviral activities against both viral entry (1.00±0.37 vs. 0.46±0.12, t=2.42, P<0.05) and viral replication (1.00±0.43 vs. [6.18±0.95]×10-4, t=3.98, P<0.05).@*Conclusions@#Our pangolin coronavirus GX_P2V is a workable model for 2019-nCoV research. CEP, selamectin and mefloquine hydrochloride are potential drugs for treating 2019-nCoV infection. Our results strongly suggest that CEP is a wide-spectrum inhibitor of pan-betacoronavirus, and clinical trial of CEP for treatment of 2019-nCoV infection is warranted.

2.
Braz. j. pharm. sci ; 49(4): 837-843, Oct.-Dec. 2013. ilus, tab
Article in English | LILACS | ID: lil-704116

ABSTRACT

The present study developed and validated an HPLC method for the simultaneous determination of artesunate (AS) and mefloquine hydrochloride (MQ) in fixed-dose combination tablets, according to ICH guidelines. The chromatographic separation was carried out on an XBridge C18 (250 x 4.6 mm i.d., 5 µm particle size, Waters) analytical column. The mobile phase included a 0.05 M monobasic potassium phosphate buffer (pH adjusted to 3.0 with phosphoric acid) and acetonitrile (50 + 50, v/v). The flow rate was 1.0 mL/min, and the run time was 13 minutes. A dual-wavelength approach was employed: AS detection was performed at 210 nm and MQ was detected at 283 nm, using a diode array detector. Stability of sample solutions was evaluated for 8 hours after preparation, during which time the solutions remained stable. Youden's test was employed to evaluate robustness. The method proved to be linear (r²>0.99), precise (RSD<2.0%), accurate, selective, and robust, proving to be appropriate for routine drug quality control analysis.


Um método por cromatografia a líquido de alta eficiência para a determinação simultânea de artesunato (AS) e cloridrato de mefloquina (MQ) em comprimidos em dose fixa combinada foi desenvolvido e validado, de acordo com as normas do ICH. A separação cromatográfica foi realizada com uma coluna analítica XBridge C18 (250 x 4,6 mm d.i., partículas de 5 µm, Waters). A fase móvel foi constituída de tampão fosfato monobásico de potássio 0,05 M (pH ajustado para 3,0 com ácido fosfórico) e acetonitrila (50 + 50, v/v). O fluxo da fase móvel foi de 1,0 mL/min e o tempo de corrida foi de 13 minutos. Utilizaram-se dois comprimentos de onda: a detecção do AS foi realizada em 210 nm e a de MQ foi realizada em 283 nm, utilizando-se um detector de arranjo de diodos. A estabilidade das soluções padrão e amostra foi avaliada por 8 horas após sua preparação e as soluções permaneceram estáveis nesse período. O teste de Youden foi empregado para a avaliação da robustez do método. O método se mostrou linear (r²>0,99), preciso (DPR<2,0%), exato, seletivo e robusto, sendo adequado para análises rotineiras de controle de qualidade dos medicamentos.


Subject(s)
Tablets/analysis , Mefloquine/analysis , Chromatography, High Pressure Liquid/methods , Pharmaceutical Preparations/analysis
SELECTION OF CITATIONS
SEARCH DETAIL